All cooling towers are factory assembled to the fullest extent possible for ease of installation and shipment. The following features are standard Delta Cooling Tower PARAGON® Series Induced Draft Cooling Towers.
 
Shell:
A seamless engineered polyethylene cylindrical (HDPE) molded shell, with conical transition for motor/fan assembly and louvered air inlets designed for 360° air distribution and fitting connection orientation. There are no joints, seams, panels, gaskets or hundreds of bolts, fasteners or caulking like conventional towers. Delta provides a 15 year warranty on the structural shell.
Water Distribution System:
A self propelled PVC distribution system incorporating a rotating sprinkler head and lateral distribution arms with integral drift eliminators. An inspection port is provided in the cooling tower shell at the lateral arm elevation for adjustment.
Wet Decking:
A continuous wrapped spiral configuration of lightweight PVC, bonded and packed for maximum film cooling efficiency.
Fan Assembly:
The fan assembly consists of a fan ring, prop, motor and guard. The fan ring is coated with premium plasite coating ideal for the harshest corrosive environments. An adjustable pitch propeller fan, fiberglass reinforced polypropylene with a silica alloy hub, is directly driven by a totally enclosed VFD rated motor designed for cooling tower duty. A fan guard is included that allows protection from the propeller and access to the motor.
Totally enclosed air over (TEAO) VFD rated motor with 1.15 service factor, designed for 208 or 230/460 volt, 3 phase 60 cycle operation and suitable for outdoor service. Motor is warranted for 5 years by the manufacture.
PVC fittings are provided for inlet, outlet, overflow, drain, and make-up connections at standard orientation locations. However, orientation for special requirements is available for new and replacement installations.
Hardware:
All fasteners are 304 stainless steel. Standard anchor and lifting lugs are aluminum.
 
 