Cooling Towers Options

Steel Mounting Platform

 

This option is beneficial in installations where a flat and level surface is not available for mounting Delta's cooling towers. This steel platform is also utilized for replacement installations where only "I" beams, or other forms of support exist. The platform may be shipped in two separate pieces, for transportation purposes, and must be supported in the field by others. This steel platform is finished in a black semi-gloss alkyd paint.

 

Skid Mounting Assembly
The skid mounting assembly is a desirable option which minimizes the field labor required to install a Pioneer® cooling tower. Included with this option is a steel mounting platform finished in a black semi-gloss alkyd paint, with the cooling tower and blower assembled and mounted to the platform. Guy Wires are included and assembled to stabilize the tower onto the platform. Additional options can readily be mounted onto the platform to complete the factory assembly. These options include blower hood, influent and/or effluent pumps, pre-piping of the pumps, mounting of a control panel, and pre-wiring of the control panel.
Ladder
The ladder assembly facilitates access to the upper section of the cooling tower for inspection and maintenance of the water distribution system and fan assembly as required. The assembly is fabricated of aluminum for lightweight installation and has skid resistant rungs and landing platform. The landing platform is specifically placed to maximize accessibility to the manway located in the conical section of the tower for easy access and servicing of components.
Safety Cage
Complementary to the ladder option and is to the ladder at the factory for ease of unit extends above the landing platform. This assembly is attached directly installation. The cage assembly is manufactured of the same type of aluminum as the ladder.
Upper Platform Safety Handrails
An optional upper platform/fan deck with safety handrail system is available on the Premier™ and TM SeriesPREMIER™ models to provide protection while on top of the cooling tower inspecting or working on the mechanical equipment. This option is shipped pre-fabricated for assembly in the field.
Blower Guard
The Pioneer® blower guard offers protection from accidentally contacting the rotating components of the fan such as the wheel, shafts and the v-belts.
The blower guard is also utilized as a screen for outdoor installations to prevent leaves and other debris from entering the tower through the double sided blower inlets.
The guard is fabricated of PVC coated 3/8" #2 wire mesh screen attached to the blower frame with stainless steel fasteners.
Blower Hood
The Pioneer® blower hood completely encloses the blower to offer maximum protection to personnel who might accidentally contact the rotating components.
The blower hood provides protection against rain and windblown debris entering the standard double inlet blower assemblies. It also protects the motors and drives from water spray which may affect their operation.
Furthermore, the hood offers an aesthetic quality to the blower assembly because it is molded from the same high density polyethylene material as the tower shell and its appearance is, therefore, consistent with the tower shell.
The hood also serves as an additional sound dampening device for the already quiet standard Delta blower assemblies. With these hoods properly installed, a 3 dBA reduction at 5 feet is common.
The hood inlets are covered with a PVC coated 3/8" #2 wire mesh screen fastened to the hood with stainless steel hardware.
Mastic Coating of Blower Assembly
Mastic coating of the Pioneer® blower wheel, housing and frame is desirable when additional corrosion protection is required. The mastic coating is applied directly over the standard enamel finish. This option is recommended in areas of continuous high humidity. It also provides protection from corrosive compounds, acids, etc. The material used is a brush on, solvent based, asphaltic film coating which is impervious to standing water and airborne spray. Mastic coating has proven successful in prolonging the average life of a standard blower assembly. After final assembly, the blower shaft and sheaves are coated with a special shaft coating material. This coating conforms to MIL-C-16173D, GR 1 & 4. For best results, periodic recoating of both the wheel and housing is recommended.
Premium Blower Corrosion Protection
Premium Pioneer® blower corrosion protection is desirable when the unit will be operated in highly corrosive atmospheres such as paper mills, coastal areas, chemical plants, etc. The premium blower corrosion protection option consists of complete PVC encapsulation of the blower wheel and housing and frame. A T-304 stainless steel shaft is also included. This option offers a cost effective alternative to FRP blower assemblies. The blowers and frames are prepared at the factory with all holes and cutouts completed. The entire assembly is sandblasted, then dipped in a molten PVC solution which coats the entire surface. When dry, the PVC attains an average thickness of 30 mils and forms a complete covering of the standard frame and housing. The blower wheel is coated in the same manner, except for the shaft bore, and is then re-balanced both statically and dynamically.
After final assembly, the shaft and sheaves are coated with a specially formulated shaft coating material which conforms to MIL-C-16173D, GR 1 & 4. The result is a blower assembly which will give years of corrosion free service even under the most adverse conditions.
Two Speed Motor Option
Two speed motors provide cold water temperature control by means of airflow modulation, allowing for design cold water temperature at minimum operating cost. When provided with a two stage thermostat, the motor can be reduced to half speed when cold water sump temperature approaches design. The motor will shut off when the cold water temperature falls below design.
Two-speed motors are provided for single voltage 3 phase operation only. Single phase dual voltage motors are not available.
  • NOTE: A 1/2 reduction in motor speed corresponds to a 1/2 reduction in airflow. At half speed operation, only 1/8 BHP is consumed.
  • Blower Thermostats - Single and Two Stage
    The fan thermostat is used to minimize operating costs by sensing water temperature and controlling blower operation during cold or cool weather service. When cold water temperature drops below design, the blower will shut off saving motor hp operating costs and serves as an antifreeze device.
    A single stage thermostat controls the blower on and off and is provided with standard single speed motors. A two stage thermostat is required for two speed motor operation and controls the blower from "on" to "half speed" and then to "off". At half speed operation the motor operates at only 1/4 full load BHP. Two stage thermostats must be wired to Delta specifications.
    The thermostat has a 5° F differential in its operating range of 30°F to 130°F. The contacts are SPDT and have a 15 Amp UL rating. They are complete with NEMA 4 enclosures suitable for outdoor mounting.
    The thermostat can be provided loose, or installed in the cooling tower sump, or an indoor storage tank.
    Vibration Cut Out Switch
    The vibration cut-out switch option helps prevent further potential damage by shutting the motor off. It is wired in series with the motor starter coil and has dry contact rating of 10 ampere capacity at 120 VAC.
    Resistance Heating Option
    The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.
    This option is provided when draining the system during periods of prolonged shutdown is not feasible, such as during weekends, or when a separate gravity feed indoor storage tank is not part of the re-circulation system.
    Protection is provided by resistance heating of the sump water, and this package includes the following components:
  • Immersion Heater - Capacity sized for service. NEMA 4 enclosure.
  • Thermostat Assembly - NEMA 4 enclosure with SPDT switch. 30-130°F temperature range. 120/277 Volt with 3/4"
    Sch 80 bulkhead fitting and a 3/4" x 1/2" Sch 40 reducer. Thermostat is to be set in the field. Recommended setting is approximately 38°F.
  • Liquid Level Switch Assembly - NEMA 7 and 9 enclosure is standard on this SPDT level switch. This insures that the heating element is submerged prior to energizing to prevent immersion heater burn-out in case of low water level.
  • Heater Contactor -NEMA l enclosure is standard. Open style for control panel mounting is available. This contactor is mounted in the control panel when the panel is purchased from Delta.
  • Protection of external piping by heat tracing and insulation is recommended but not included.
    Antifreeze Package - Electrically Activated Drain Valve
    This option is utilized when freezing of standing water in the cooling tower sump could occur due to system shutdown during winter operation.
    An electrically actuated valve will open when the pumps are not operating and temperatures approach freezing. The valve can be installed in the sump drain fitting of the tower at the factory or remotely at the piping low point by others in the field.
    Components provided are:
  • Electrically actuated to close, spring to open, 2-way valve, 1" line size, with NEMA 4 enclosure.
    When power is removed the valve automatically reverts to the open position. This feature ensures freeze protection even during a power outage.
  • 1" PVC tee
  • 1" PVC plug
  • Temperature switch with bulkhead fitting
  • Motor Space Heater
    Fan Motor Space Heaters are recommended for installations where temperature variations can cause excessive condensation within the motor. The Space Heater controls can be incorporated in our Control Panel and would be designed for automatic and manual operation. While the motor is operating, the heater remains off. When the motor shuts down, the heater is automatically energized during the off cycle. The Control Panel would be designed with manual on/off control for intermittent cycles of operation. Heaters are available for 115, 230, 460, or 550 volts, 3 phase, 60 cycle operation.
    Outlet Strainer Basket
    This option is desirable to prevent debris which may have entered the cooling tower sump from getting into the pump, or the rest of the cooling water system. This option is recommended to minimize particle size which could foul chillers, heat exchanger, compressors, or the cooling tower nozzles.
    A vortex breaker pipe, which is provided as standard on pump suction applications, is included to maximize the inlet area and prevent cavitation. The strainer is made from a vortex breaker pipe surrounded by 3/16" #2 PVC coated mesh screen. Finer mesh screens can be overlaid to minimize particle size.
    High Sump Level Switch
    The high sump level switch option is utilized when a potential overflow condition must be avoided. Level switch elevation is set below the point when the water in the sump will overflow onto the ground. The switch can be used to illuminate a light, shut off the influent feed pump or initiate some other device or alarm.
    Flange Adapters
    This option provides 125 lb. Schedule 80 PVC flanged connection at approximately 6" projection minimum from the cooling tower. Gaskets and hardware are not provided by Delta and should be provided by others with the piping companion flange.
    Equalizer Fittings
    This option is desirable for multiple module installations to provide equal liquid levels in the sumps of the individual modules and allows for the installation of only one water make-up line.
    Delta provides the bulkhead fittings installed in the cooling towers to provide for gravity flow from one tower sump to another. The equalizer connection is not for full flow transfer, i.e. pumping from one unit to another.
    The connecting piping should be field installed and is the responsibility of others.
    Bottom Outlet
    A bottom outlet provides for complete drainage of water from the cooling tower sump. This option is attractive when indoor tanks are utilized for complete drainage of the cooling tower. This prevents standing water from possibly freezing and damaging PVC piping.
    Pump(s)
    The pump package is offered to allow for single source responsibility of cooling tower equipment. The size of the pump is determined by two factors:
    1. Flow rate (gpm)
    2. Total dynamic head. (feet)
    The customer is responsible for supplying this information. The pumps come complete close coupled with mechanical seals and ODP, 208-230V/460V, 3 phase motor. TEFC motors are available.
    Pump Mounting
    This option is available when the skid mounting option is also selected. A pump is mounted into the platform and the suction is pre-piped with PVC Sch. 80 pipe and fittings. This reduces the amount of field labor involved in installing a cooling tower system.
    Control Panels
    A control panel is required any time there are electrical devices involved in a system. The standard features of a Delta supplied control panel are:
  • NEMA 12 enclosure.
  • Starters with integrally mounted thermal overloads with manual or automatic reset.
  • Terminal block connections for all incoming leads.
  • Control circuit transformer with primary and secondary fuses.
  • NEMA 12, two or three position selector switches and lights for all starters provided.
  • Color coded and numbered control circuit wires.
  • Wiring diagram permanently affixed inside enclosure.
  • Optional items available are:
  • Disconnect switch, either fused, unfused or magnetic circuit breaker type.
  • Motor starter fuses or circuit breakers.
  • Additional motor starters, selector switches and lights to interface with existing systems. remote pumps. etc.
  • Any other NEMA enclosure manufactured.
  • Pre-mounting of control panel and pre-wiring of skid mounted options with Liquid-Tite conduit or EMT.
  • Delta also can provide programmable controllers, computer interfacing, telemetry, and any other type of control system required. Pre-mounting and pre-wiring of the control panel for a system installation are available. This minimizes the labor required for field installation.
  • Storage Tanks
         
    The tank is utilized when extra water capacity is required. Potential applications are for system modulation when pumping flow rates vary, or for additional water storage. A hot/cold tank arrangement may be required in those cases where the process hot water exceeds the maximum allowable inlet water temperature (140°F). This is a dual loop system where the cooling tower would typically flow more water than the process. The difference in flow would be made up and mixed with the hot water to reduce its temperature. The tank and optional cover are fabricated of high density polyethylene. All fittings are Type 1 PVC. Standard capacities are 300 to 2000 gallons, others are available.
     